Command: *20*
Description: The siren feedback sound is off when you press remote control, only have buzzer sound.
6.10 Buzzer sound on/off:
Command: *99* The buzzer sound: OFF
Command: *98* The buzzer sound: ON.
6.11 Register and Delete remote controller/sensors:
Register Remote controller:
Command: *0*
Description: After pressing *0* on the alarm panel keyboard, then press any button of the remote controller
within 10 seconds. A long “Beep” sound means successfully.
Register Sensor:
Command: *01*
Description: After pressing *01* on the alarm panel keyboard, then trigger the sensor within 10 seconds. A
long “Beepi” sound means successfully.
Command: *03*
Description: Learning wireless keypad.
Assigning Zone Number;
Command: *8xx*
Description: xx = 00-99 zones number, ex: *816*, assign the register sensor to zone 16.
Delete all Remote Controllers
Command: *02*
Description: Delete all of the remote controllers
Delete all Sensors
Command: #8996#
Description: Delete all detectors.
6.12 Zone mode settings:
Command: #8xxA#
Description:
xx = 00-99 (zone number);
A= zone mode (0-7) 8 modes
0: Bypass mode: The selected zone is disabled at all time
1: Common mode: The selected zone is active when the system is arming
2: Intelligent mode: The selected zone is disable when system INTELLIGENT ARMING
3. Emergency mode: The selected zone is active at all time even the system is not arming
i.e; Smoke, Gas, Heat, Emergency panic sensors, …
4. Multi-Zones Triggered Mode: The selected zone is assigned to the Multi-Zones mode and
the alarm condition is triggered when 2 or more zones in this mode are active within 30
seconds.
5. Delay-alarm mode: When the selected zone is active the system will enter the delay
alarm mode.
6. Repeat triggered mode: when the detector in the selected zone is triggered once, the
system will not alarm immediately, only when it is triggered again within 30 seconds after
the first trigger, the system will alarm.
8. Doorbell mode: The control panel will sound “ding dong” as the doorbell when the
selected zone is active.