6.1.14 Zone mode settings:
Command: #8xxA#
Description:
xx = 00-99 (zone number);
A= zone mode (0-7) 8 modes
0: Bypass mode: The selected zone is disabled at all time
1: Common mode: The selected zone is active when the system is arming
2: Intelligent mode: The selected zone is disable when system INTELLIGENT ARMING
3. Emergency mode: The selected zone is active at all time even the system is not arming
i.e; Smoke, Gas, Heat, Emergency panic sensors, …
4. Multi-Zones Triggered Mode: The selected zone is assigned to the Multi-Zones mode and
the alarm condition is triggered when 2 or more zones in this mode are active within 30
seconds.
5. Delay-alarm mode: When the selected zone is active the system will enter the delay
alarm mode.
6. Repeat triggered mode: when the detector in the selected zone is triggered once, the
system will not alarm immediately, only when it is triggered again within 30 seconds after
the first trigger, the system will alarm.
8. Doorbell mode: The control panel will sound “ding dong” as the doorbell when the
selected zone is active.
6.1.15 Alarm event history:
Command: x
Description: x = (0-9) press key 0~9 to inquiry the latest 10 alarm events and display alarm defense area (0
means the most recent event).
6.1.16 Telephone line tampering detection:
Command: *51* Description: the system will alarm when telephone lines disconnect or failure
Command: *50* Description: the system will not detect telephone lines disconnection or fault.
6.1.17 Remote controller enable/disable:
Command: *31* Description: Remote controller is disabled.
Command: *30* Description: Remote controller is enabled
6.1.18 Remote control output OUT:
Command: #80A#
Description: A = 0-9
0: OUT line out is disabled
1: OUT line out is only active in the DISARMING mode
2: OUT line out is only active in the Intelligent ARMING mode and during the alarming period.
3: OUT line out is only active in the Intelligent ARMING mode and is disable during the alarming period.
4: OUT line out is only active in the ARMING mode and during the alarming period.
5: OUT line out is only active in the ARMING mode and is disable during the alarming period
6: OUT line out is only active in any ARMING condition mode and during the alarming period.
7: OUT line out is only active in any ARMING condition mode and is disable during the alarming period
8: OUT line out is active in the alarm mode
9: OUT line out is active
6.1.19 Setting up the system time and timing ARM/DISARM:
Command: *07HHMM* System time setting
Description: HH = hour (0-23) , MM= minute (0-59); Ex: *071830*, means set up the time to be 18:30
Command: #07HHMMA# Alarm arming timer
Description HH = hour (0-23) , MM= minute (0-59); Ex: *071830*, means set up 18:30
A = 0-9: 9 group of alarm timing can be programmed: 0 = disable arming timer; group 1 to group 5 timer can
be used repeatedly, group 6 to group 9 timer can be used only one time; Ex: #0700000# all timer off.